Gas Furnaces
Products
 
 
Models
TM9T

Capacities
60 - 120 MBH

Efficiency
96% AFUE

Warranty
Heat Exchanger - Lifetime
Other parts - 10-Year Limited*

 
Two-Stage Multi-Position 33 Gas Furnace

These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications.
These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation.
These units are Category IV listed and may be vented either through side wall or roof applications using approved plastic combustion air and vent piping.


Special Benefits
  • Two stage heating operation includes two stage gas valve, two stage inducer operation and 4 speed, direct drive PSC motor blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat.
  • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary.
  • Compact, easy to install, ideal height 33" tall cabinet.
  • Blower-off delay for cooling SEER improvement.
  • Easy access to controls to connect power/control wiring.
  • Built-in, high level self diagnostics with fault code display.
  • Low unit amp requirement for easy replacement application.
  • All models are convertable to use propane (LP) gas.
  • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.
  • 100% shut off main gas valve for extra safety.
  • 24V, 40 VA control transformer and blower relay supplied for add-on cooling.
  • Hi-tech tubular aluminized steel primary heat exchanger with stainless steel tube/aluminum fin secondary heat exchanger for outstanding efficiency.
  • Solid removable bottom panel allows easy conversion.
  • Airflow leakage less than 1% of nominal airflow at ductblaster conditions.
  • No knockouts to deal with, making installation easier.
  • Movable duct connector flanges for application flexibility.
  • Quiet inducer operation.
  • Inducer rotates for easy conversion of venting options.
  • Fully supported blower assembly for easy access and removal of blower.
  • External air filters used for maximum flexibility in meeting customers IAQ needs.
  • Insulated blower compartment for thermal and acoustic performance.
  • 1/4 turn knobs provided for easy independent door removal.
  • Internal condensate trap design (patent pending) provides condensate management options, easy visual operation check, and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent or condensate blockage.
  • Venting applications maybe installed as either 2 pipe sealed combustion or single pipe vent using indoor combustion air.

*Must be installed on or after May 1st, 2009, and registered online within 90 days of installation. Otherwise, the warranty reverts to the standard warranty as published in the product warranty certificate. This warranty does not apply to R-22 or 3-phase models.


Publications and Manuals
DescriptionPart NumberFile Size
Consumer Brochures
Consumer Brochure - TM9T LX™ 9T Series 96% AFUE 33" Furnaces PUBL-6220-A-0909816 KB
 
Tech Guides
Technical Guide - TM9T 96% AFUE Two-Stage Multi-Position 33" Gas Furnaces 444559-YTG-C-0210146 KB
 
Installation Instructions
Installation Manual - TM9T*MP 96% AFUE Residential Two Stage Multi-position Gas Furnace 505309-UIM-B-12092682 KB
 
Accessory Installation Instructions
Installation Accessory - 1BR0514/614, 1BR0517/617, 1BR0521/621 & 1BR0524/624 External Bottom Mount Filter Frame Acessory 506177-UAI-A-030937 KB
Installation Accessory - 1HT0901 Side Wall Vent Kit 246178-UAI-A-080447 KB
Installation Accessory - 1HT0902 Side Wall Vent Kit 276016-UAI-A-1006125 KB
Installation Accessory - 1NP0347 Propane Conversion - Induced Combustion Furnaces 247585-UAI-F-0210219 KB
Installation Accessory - 1SR0402 Filter Frame 430731-UAI-A-090838 KB
Installation Accessory - S1-1PS3308 (96%) and 1PS3309 (80%) High Altitude Application Conversion for Two Stage Furnaces 035-22764-001-D-011023 KB
Installation Accessory - S1-32642583000 and S1-3264594000 Inducer Replacement Kits 035-22216-002-C-031098 KB
Installation Accessory - S1-33102954000 Ignition Control P/N 035-22271-001-A-0409131 KB
Installation Accessory - S1-37327813001 Furnace Label Kit 341248-UAI-A-070711 KB
Installation Accessory - S1-37327905001 thru S1-37327905006 (2 Cell thru 7 Cell) 33" Burner Box Kits for all 33" Gas Furnaces 533818-UAI-B-021099 KB
 
Submittal Drawings
Submittal Data Sheet - TM9T 96% AFUE Two-Stage Multi-Position Gas Furnaces 444564-USD-A-040994 KB
 
Repair Parts
Repair Parts - Condensate Pan Replacement for Use with All Condensing - 95+ AFUE 33" Gas Furnaces 035-22785-001-B-031067 KB
Repair Parts - TM9T and TM9V Series Furnace Pressure Switch Wiring Harness. 035-22781-001-A-100983 KB
Repair Parts - TM9T Series 95% AFUE Two Stage Multi-Position 33" Gas Furnaces "Style A" 035-22270-001-B-0909711 KB
 
User Manuals
User Manual - All Residential Multi-Position 33" Gas Furnaces 356486-UUM-I-08092386 KB
 
Miscellaneous
Quick Reference Guide - 96% AFUE Two Stage Multi-Position 33" Gas Furnaces 505310-URG-B-0509258 KB