Evaporator Coils
Products
 
 
Models
PC

Capacities
2 - 5 Tons

Efficiency


Warranty
Other parts - 10-Year Limited*

 
PC - Half Cased Evaporator Coil

These cooling and heat pumpcoils are designed to be installed with York furnaces and to be matched with York cooling and heat pump outdoor units.  All coils utilize a TXV to provide our customers with the optimum performance and refrigerant control required for 13+ SEER  systems.  Coils can be ordered with a R22 TXV factory installed that can be easily converted to R410A by changing the bolton TXV.


 


"Flex-coils" are also available without a factory installed metering device.  For added application flexibility a R22 or R410A TXV is installed, on "Flex-coils", in the field to meet your refrigerant choice. 


 


Partial Cased Coils - Designed for high-efficiency to match any system, full cased in the upflow or downflow and the partial cased in the upflow only application.


Special Benefits
  • Thermal Expansion Valve – Provides flexibility to convert any coil to R22 or R410A refrigerant.  A true bolt-on TXV, valve assembly and equalizer tube are bolt-on, no brazing required.  TXV and sensing bulb are mounted inside the cased coil cabinet.  (Must be field supplied for all “Flex-coils”)
  • Insulated Cabinet – All evaporator coil cabinets are thermally insulated with foil faced insulation to prevent sweating.
  • Internally Clean – All evaporator coils are factory leak-tested, dehydrated, sealed and shipped with a holiday charge.  The suction and liquid lines are sealed with rubber plugs, no cutting of connection stubs to attach line set. 
  • Durable Finish Inside and Out ­– Coil casings are made of prepainted steel.  The pre-painted steel.  The pre-treated flat galvanized steel provides a better paint to steel bond, which resist corrosion and rust creep.  All internal metal parts are made of G90 pre-painted steel i.e. triangular plated, top plates, horizontal supports etc.  (Coil header plates are non-painted due to the brazing process during production.)
  • Optimum Heat Transfer - Using the latest in heat transfer technology, staggered rows of copper tubes are mechanically expanded into aluminum fins to provide optimum air to surface contact for ample moisture removal as well as high performance ratings.

*Must be installed on or after May 1st, 2009, and registered online within 90 days of installation. Otherwise, the warranty reverts to the standard warranty as published in the product warranty certificate. This warranty does not apply to R-22 or 3-phase models.


Publications and Manuals
DescriptionPart NumberFile Size
Tech Guides
Technical Guide - FC/HC/HD/MC/MH/PC/UC Add-On Coils For Use With Split-System Cooling & Heat Pumps 526001-YTG-A-0809597 KB
 
Installation Instructions
Installation Manual - MC / FC / PC Partial Cased / Full-Cased Upflow / Counterflow Cooling / Heat Pump Coils 525923-UIM-A-08091336 KB
 
Accessory Installation Instructions
Installation Accessory - S1-TVM2**, 4**, 7**, & 9** Thermal Expansion Valve Kits 166806-UAI-H-0408243 KB
 
Submittal Drawings
Submittal Data Sheet - PC/UC Add-On Coils for Split-System Cooling and Heat Pumps 331475-YSD-D-1207303 KB
 
Repair Parts
Repair Parts - PC Series Partial Cased Coils "Style A & B" - R-22 TXV & Flex Coil Models 035-20801-001-J-0708213 KB
Repair Parts - PC Series Partial Cased R-22 TXV & Flex Coils "Style H" 035-22220-001-A-1208216 KB
Repair Parts - PC Series Partial Cased R-410A TXV Coils "Style H" 035-22223-001-B-1209214 KB
Repair Parts - PC Series Partial-Cased Coils "Style A" - R-410A TXV Models 035-22187-001-B-1209213 KB
 
Warranty Information
Warranty - UPG 10 year Limited Warranty on Air Handlers and Evaporator Coils and Parts 157976-UWA-B-040929 KB